Evaluation of Gesture Based Interfaces for Medical Volume Visualization Tasks
Abstract
Interactive systems are increasingly used in medical applications with the widespread availability of various imaging modalities. Gesture-based interfaces can be beneficial to interact with these kinds of systems in a variety of settings, as they can be easier to learn and can eliminate several shortcomings of traditional tactile systems, especially for surgical applications. We conducted two user studies that explore different gesture-based interfaces for interaction with volume visualizations. The first experiment focused on rotation tasks, where the performance of the gesture-based interface (using Microsoft Kinect) was compared to using the mouse. The second experiment studied localization of internal structures, comparing slice-based visualizations via gestures and the mouse, in addition to a 3D Magic Lens visualization. The results of the user studies showed that the gesture-based interface outperform the traditional mouse both in time and accuracy in the orientation matching task. The traditional mouse was the superior interface for the second experiment in terms of accuracy. However, the gesture-based Magic Lens interface was found to have the fastest target localization time. We discuss these findings and their further implications in the use of gesture-based interfaces in medical volume visualization, and discuss the possible underlying psychological mechanisms why these methods can outperform traditional interaction methods
Attachments
No supporting information for this articleArticle statistics
Views: 246
Downloads
PDF: 249